Electrical Power, Energy and Safety
Electrical power is , and the energy transferred is . Electricity companies charge per kilowatt-hour: the energy used by a kW appliance in hour. Fuses and circuit breakers cut off the current if it gets too big; earthing a metal case makes a fault blow the fuse instead of electrocuting you.
Builds on: Series and parallel circuits
On the AQA 8463 syllabus (First teaching 2016): 4 points this lesson covers
- 4.2.3.1 Direct and alternating pd
- 4.2.3.2 Mains electricity and safety
- 4.2.4.1 Power in circuits
- 4.2.4.2 Energy transfers in appliances
Summarised in our own words from the official syllabus. Check the exact wording in the board's specification.
Learning objectives
- Use and .
- Calculate energy in kWh and its cost.
- Choose a suitable fuse rating.
- Explain fuses, circuit breakers, earthing and double insulation, and identify electrical hazards.
A washing machine has a metal case. Inside, a loose live wire touches the case. Why might nothing happen until someone touches the machine, and what stops that being deadly?
Core idea
Your bill doesn't count joules; it counts kilowatt-hours. A 2 kW kettle running for an hour uses 2 kWh. Knowing power and time lets you predict cost, and knowing current lets you choose a fuse that keeps you safe.
; ; 1 kWh J. Fuse rating just above normal current; earthing protects against shocks.
1. Power and cost
- where
- power (W).
- energy (J or kWh).
2 kW, 15 min a day, 20 cents per kWh.
- Goal
- Daily cost; energy in joules.
- Strategy
- kW × hours.
- 15 min = 0.25 h.
- Cost.
- In SI units.
2. Safety
2300 W appliance on 230 V. Fuses: 3, 5, 13 A.
- Goal
- Fuse.
- Strategy
- Normal current, then next size up.
- .
- Smallest rating above 10 A.
- Live (brown), neutral (blue), earth (green/yellow).
- Fuse and switch in the live wire.
- Earth carries fault current away, blowing the fuse.
- Double insulation: no earth needed.
Why not use a 30 A fuse everywhere?
| Feature | How it protects |
|---|---|
| Fuse | Melts and breaks the circuit if the current is too large |
| Circuit breaker | Switches off automatically on overcurrent; can be reset |
| Earth wire | Carries current safely to earth if a metal case becomes live, blowing the fuse |
| Double insulation | Plastic case cannot become live, so no earth wire needed |
| Switch in the live wire | Appliance is disconnected from the high voltage when off |
A 2.3 kW kettle runs on 230 V mains. Which fuse should it have: 3 A, 5 A or 13 A?
Summary
- ; .
- Fuse just above normal current.
- Kilowatt-hour
- Energy used by 1 kW for 1 hour.
Also on your syllabus
- Uses of electricity: heating, lighting, charging batteries, and powering motors and electronic systems.
- If a live wire touches an earthed metal case, a large current flows straight to earth through the low-resistance earth wire. This melts the fuse (or trips the circuit breaker), cutting off the supply, so the case never stays live.
- Fuses and circuit breakers go in the live wire, so that when they break the circuit the appliance is disconnected from the high voltage. In the neutral wire the appliance would stay live even after the fuse blew.
Create a free account to read the rest of this lesson: key formulae, worked examples, explore the graph, common mistakes, exam tip, guided practice and more. Your answers are checked and your progress is saved.