SA-9702-MP2-0031 markL1 FoundationCalculatorAttenuation and CT
Calculate the half-value thickness of a material with μ=50 m⁻¹, in cm. Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0041 markL1 FoundationCalculatorX-ray production
X-rays are produced in an X-ray tube when
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0051 markL1 FoundationCalculatorX-ray production
The accelerating voltage of an X-ray tube is doubled. The minimum X-ray wavelength
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0061 markL1 FoundationCalculatorAttenuation and CT
Contrast in an X-ray image between bone and soft tissue is due to
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0071 markL1 FoundationCalculatorAttenuation and CT
In CT scanning, a 3D image is produced by
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0091 markL1 FoundationCalculatorAttenuation and CT
An X-ray beam passes through 3 half-value thicknesses of a material. State the fraction of intensity transmitted, as a decimal. Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0121 markL1 FoundationCalculatorX-ray production
The target in an X-ray tube is usually made of tungsten because tungsten
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0012 marksL2 StandardCalculatorX-ray production
Calculate the minimum wavelength of X-rays from a tube operating at 30 kV, in units of 10−11 m. (h=6.63×10−34 J s; c=3.00×108 m s⁻¹; e=1.60×10−19 C) Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0022 marksL2 StandardCalculatorAttenuation and CT
Bone has an attenuation coefficient of 300 m⁻¹. Calculate the percentage of X-ray intensity transmitted through 1.0 cm of bone. Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0081 markL2 StandardCalculatorX-ray production
A contrast medium such as barium is used to image the digestive system because it
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0101 markL2 StandardCalculatorX-ray production
Calculate the maximum X-ray photon energy from a tube at 80 kV, in units of 10−14 J. (e=1.60×10−19 C) Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0113 marksL3 ExamCalculatorAttenuation and CT
An X-ray beam passes through 4.0 cm of soft tissue (μ=20 m⁻¹) and then 1.0 cm of bone (μ=300 m⁻¹). Calculate the percentage of the original intensity that emerges. Salam Academy Original Practice · Proposed mark scheme