Salam Academy
Practise

Question bank

Original exam-style questions, mapped to your syllabus. Answers are checked for mathematical equivalence and every attempt updates your mastery.

Sign in to check answers. Your attempts build your mastery and error book.

12 questions

SA-9702-MP2-0031 markL1 FoundationCalculatorAttenuation and CT
Calculate the half-value thickness of a material with μ=50\mu=50 m⁻¹, in cm.

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0041 markL1 FoundationCalculatorX-ray production
X-rays are produced in an X-ray tube when
Choose one option

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0051 markL1 FoundationCalculatorX-ray production
The accelerating voltage of an X-ray tube is doubled. The minimum X-ray wavelength
Choose one option

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0061 markL1 FoundationCalculatorAttenuation and CT
Contrast in an X-ray image between bone and soft tissue is due to
Choose one option

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0071 markL1 FoundationCalculatorAttenuation and CT
In CT scanning, a 3D image is produced by
Choose one option

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0091 markL1 FoundationCalculatorAttenuation and CT
An X-ray beam passes through 33 half-value thicknesses of a material. State the fraction of intensity transmitted, as a decimal.

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0121 markL1 FoundationCalculatorX-ray production
The target in an X-ray tube is usually made of tungsten because tungsten
Choose one option

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0012 marksL2 StandardCalculatorX-ray production
Calculate the minimum wavelength of X-rays from a tube operating at 3030 kV, in units of 10−1110^{-11} m. (h=6.63×10−34h=6.63\times10^{-34} J s; c=3.00×108c=3.00\times10^8 m s⁻¹; e=1.60×10−19e=1.60\times10^{-19} C)

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0022 marksL2 StandardCalculatorAttenuation and CT
Bone has an attenuation coefficient of 300300 m⁻¹. Calculate the percentage of X-ray intensity transmitted through 1.01.0 cm of bone.

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0081 markL2 StandardCalculatorX-ray production
A contrast medium such as barium is used to image the digestive system because it
Choose one option

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0101 markL2 StandardCalculatorX-ray production
Calculate the maximum X-ray photon energy from a tube at 8080 kV, in units of 10−1410^{-14} J. (e=1.60×10−19e=1.60\times10^{-19} C)

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP2-0113 marksL3 ExamCalculatorAttenuation and CT
An X-ray beam passes through 4.04.0 cm of soft tissue (μ=20\mu=20 m⁻¹) and then 1.01.0 cm of bone (μ=300\mu=300 m⁻¹). Calculate the percentage of the original intensity that emerges.

Sign in or create a free account to check answers, get hints and track your progress.

Salam Academy Original Practice · Proposed mark scheme