PractiseQuestion bank
Original exam-style questions, mapped to your syllabus. Answers are checked for mathematical equivalence and every attempt updates your mastery.
Sign in to check answers. Your attempts build your mastery and error book.
12 questions
SA-9702-MP3-0031 markL1 FoundationCalculatorTracers
The radioactive tracer used in PET scanning decays by
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0041 markL1 FoundationCalculatorAnnihilation
When a positron and an electron annihilate at rest, two photons are emitted in opposite directions because
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0061 markL1 FoundationCalculatorTracers
A radioactive tracer is
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0081 markL1 FoundationCalculatorAnnihilation
State the energy of each annihilation photon in MeV.
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0121 markL1 FoundationCalculatorTracers
Compared with an X-ray image, a PET scan mainly shows
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0012 marksL2 StandardCalculatorAnnihilation
An electron and a positron at rest annihilate. Calculate the energy of each photon produced, in units of 10−14 J. (me=9.11×10−31 kg; c=3.00×108 m s⁻¹) Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0021 markL2 StandardCalculatorAnnihilation
Calculate the wavelength of a 8.2×10−14 J annihilation photon, in units of 10−12 m. (h=6.63×10−34 J s; c=3.00×108 m s⁻¹) Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0052 marksL2 StandardCalculatorAnnihilation
Photons from an annihilation arrive at opposite detectors with a time difference of 0.40 ns. Calculate how far from the midpoint between the detectors the event occurred, in cm. Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0071 markL2 StandardCalculatorTracers
PET tracers are chosen to have short half-lives so that
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0091 markL2 StandardCalculatorTracers
Fluorine-18 has a half-life of 110 minutes. A dose has activity 400 MBq at injection. Calculate its activity 330 minutes later. Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0101 markL2 StandardCalculatorAnnihilation
In a PET scanner, an annihilation event is recorded when
Salam Academy Original Practice · Proposed mark scheme
SA-9702-MP3-0113 marksL3 ExamCalculatorAnnihilation
A positron with kinetic energy 0.25 MeV annihilates with an electron at rest. Calculate the total energy of the two photons produced, in MeV. Salam Academy Original Practice · Proposed mark scheme